No insulation is truly fireproof, but mineral wool won't feed a fire, and a fire-rated coating lets spray foam meet fire code. We install mineral wool batts, coat exposed foam and close the hidden gaps around chimneys and chases in Greenville homes, garages and shops. Ask for a free estimate and tell us what worries you.
Not in the strict sense, but the materials are very different. Mineral wool is made from stone and doesn't burn, so it's our pick where fire resistance matters. Unfaced fiberglass batts don't fuel a fire much either, but paper facings can burn.
Foam plastic insulation is the one that needs a covering to meet fire code. We go through that below.

Use mineral wool where you want a wall, ceiling or floor to slow a fire down. We friction-fit the batts into open cavities, including fire-rated batts for interior walls and between floors. They install to the maker's instructions and go in tight, with no gaps.
The same batts quiet a room, which is why they suit a shop wall or a ceiling over living space. Our ROCKWOOL mineral wool page covers the material, where it's worth the money and where it isn't. For the noise side, see soundproofing insulation.
Spray foam left exposed needs a fire-rated covering. In attics, crawl spaces, garages and metal buildings, we spray an intumescent coating over the foam to meet fire code. The coating swells under heat and shields the foam underneath.
A foam surface in or next to living space is held to a stricter standard than a bare attic roof deck. The covering can be an ignition barrier or a full thermal barrier, and the one you need depends on the space. We confirm the code wording for your building at the estimate, before we quote it.
New to foam? Start with spray foam insulation and the open cell vs closed cell guide. The pros and cons page gives the honest downsides.
Fire blocking is a solid, noncombustible stop in the hidden gaps of a house. It keeps flames and hot gases from climbing through a wall, a chase or the space around a chimney.
Before we insulate an attic or wall that has a chimney, flue or chase in it, we look at those gaps first. Insulation stays back from the flue as the maker's instructions and the code direct. We close open gaps with noncombustible material rather than stuffing them with insulation.
Insulating the attic or walls as well? See attic insulation and wall insulation.
If your garage doubles as a workshop, fire is a bigger question than in a bedroom. Welders, grinders, a wood stove or a space heater all throw sparks or heat.
Exposed foam on shop walls and ceilings gets the fire-rated coating. Mineral wool batts fit open stud walls and the ceiling under a room above. Our garage insulation page covers the walls, ceiling and attic side of the job.
For a steel shop or pole barn, see metal building insulation. Larger shops and warehouses are on our commercial insulation page.
Our installed price for the fire-rated coating over exposed foam is $1 to $1.50 per square foot of foam surface coated. That covers intumescent coating sprayed over exposed foam in attics, crawl spaces, garages and metal buildings to meet fire code.
Price moves with access, job size and the thickness of coating the code requires. It also moves with ignition barrier versus full thermal barrier. Our insulation cost page goes through the rest. The free estimate gives the exact price for your building.
Uncovered foam can burn and give off heavy smoke, which is why code asks for a barrier over it. We install foam to the maker's instructions and cover it the way the code asks.
Tell us which wall, ceiling, foam surface or chimney gap worries you, and we'll come look. You get a written scope and a price for your building.
Licensed & insured · Free estimates